Sensor methodInstallation methodother hardware neededmax installation heightFunctioning methodmax Detection areaIcon decayConfiginfo availableadvised for utilization?
PIR (Tabs)*wireless (tape)hub+sensors per seat/chair2.15m (7ft) to 4m (13.12ft)https://confluence.mcs.be/display/SUM/Tabs+%28Tracknet%29+PIR+Sensor+way+of+measuring4m x 10m (13,12 x 32,81 ft)15minStudioLive Floorplan+Dashboards- possible for utilization in open spaces
- not advised for utilization in meeting rooms (difficult/technical set-up; not possible to detect over-utilisation + risk of false positive/negatives is bigger, eg people standing up in the room or people walking around the chairs while on the phone)
Footfall (Pointgrab)wirednone2.15m (7ft) to 4.5m (14.8ft)in/out-traffic8m x 1m (26 x 3 ft)2minCPMS + StudioLive Floorplanother options are more reliable (footfall method very sensitive)
Actuator LOGIClink (LOGICdata)wireddrive/motorNA

https://confluence.mcs.be/display/SUM/LOGIClink+%28LOGICDATA%29+installation+guide

 

NA15minconfig toolLive Floorplan+Dashboards- possible for utilization in open spaces
- not advised for utilization in meeting rooms (difficult/technical set-up; not possible to detect over-utilisation + risk of false positive/negatives is bigger, eg people standing up in the room or people walking around the chairs while on the phone)
AirthingswirelesshubNAestimate based on size of the room + CO2 => combination of parameters50m2 (538,2 sq ft)15minAirthings + Studionot yet integratedother options are more reliable

...

Setting up Indirect utilization (with PIR): Each SEAT needs to be a real WORKPLACE

  • Make sure each conference meeting room seat corresponds to a workplace
  • IWMS "Workplaces" objects to be created in/under the correct ROOM object, which in turn should be in the correct room category -> make sure room categories are correctly mapped in Studio
  • Make sure the capacity for meeting rooms is set correctly in Studio (ref Room Capacity)
  • Reminder: Workplaces Workplace objects can only be linked to SVG floorplans in Studio

...

  • Occupancy
    • Presence on room level is true in case presence is true for 1 or more workplaces seats OR if presence is true for the sensor linked to the room itself
      • So if someone walks around in the room, where workplace seat PIRs are not triggered, but room PIR is triggered -> presence = true
  • Utilization
    • If presence detected on workplaces seat level AND room level, headcount will only be calculated based upon sum of triggered workplacesseats. It ignores the room PIR.
      • So if 2 people sit on a chair/seat triggered by workplace PIR, headcount will be 2
    • If presence detected ONLY on room level and not on workplacesseats, headcount is set to minimum 1
      • So if someone walks around in the room, but workplace seats PIRs not triggered, headcount is 1

...

  

Quarter 1

Quarter 2

Quarter 3

Occupancy

Room PIR

0

1

1

Wp Seat 1 PIR

1

1

0

Wp Seat 2 PIR

1

1

0

Wp Seat 3 PIR

0

0

0

 

Room occupancy live floorplan

TRUE

TRUE

TRUE

 

Room utilization live floorplan

2

2

1

 

Room utilization count timeslots

2

2

1

...

Occupancy on live floorplan shows: location occupied or not (independent of how many people there are in that location)

Image RemovedImage Added

 

Utilization on live floorplan shows: how many people are detected therein that location

Image RemovedImage Added