Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Table of content

Table of Contents

...

Configuration ON Tabs hardware

Hub – Gateway

Configuring the Hub will let you set up the Hub as a router, WIFI client, WIFI extender, or WIFI off. It will also let you choose between DHCP and Static IP for ethernet based connections.
Step 1. Check the firmware version
Step 1.1 Go to the trackio grafana platform
Step 1.2 Open router mamagement
Step 1.3 Locate the hub
Step 1.4 Check if the current firmware version is 1.25.02 or later
Step 2. Factory reset the hub with internet unplugged.
Caution! If the hub is connected to the internet it will reconfigure to the standard MCS configuration
Step 3. Join the hubs initial open Wi-Fi network (Tabs-xxxxxxx)
Step 4. Open the configuration html
Step 5. Follow the configuration steps of the configuration tool.

View file
namehubsetup.html
height250

...

Motion sensor – PIR

There are 5 different parameters that effect the behaviour of a TrackNet motion sensor. Sensitivity, Blind time, pulse counter, window time, and filter type.
Each of these parameters can be altered by sending a downlink to the sensor from the trackio platform.
For calculating the downlink code use the latest version of the downlink encryption sheet.
For configuring multiple sensors at once use the latest version of the downlink configuration program.

...

...

Healthy home – Comfort

This sensor can not be configured.

...

Door & Window switch

This sensor can not be configured.

Deploying sensors in Bohemian

Inquire the list of the sensors (Sensors ID) and import those into Bohemian https://studio.cobundu.com/app/bohemian.

  • for TABS motion sensors: You can either check for Tab sensor IDs with your customer or you can request in your MCS ticket following the hardware shipment (ref Request Cobundu hardware) from which boxes were the sensors taken?
    In the following documents, you will find inventory files. Sensors are treated First In First Out.

    If you just filter on the box numbers you’ll see all the sensors in that box.

    ! Please mind: there are 100 sensors in 1 box, so in case your customer did not buy a multiple of 100, some IDs mentioned in this list do not belong to your tenant.


You should use download/upload excel function of the bohemian with correct sensor ID, Sensor Model and organization.

...

Please be aware that only after the next data package is send, data for this sensor will be visible in your tenant. (This means that depending on time of upload to Bohemian and activity at the customer site, this can take a while.)

Deploying sensors in Studio

Provide the rooms template and floor plans to the customer.
A clear indication of the area where the sensors must/will be installed and additional column for the sensors IDs should be available on the sheet.
As described in the installation guide, note 8 last digits of the sensor number in “Sensor ID #” column.
Concerning the TAB sensor, be aware that there are 2 numbers on a sensor, the ID that starts with 58-A0-CB-00 is the one that we need during the configuration.

...

Caution: When you choose your location, you will see that there are 2 options for the same location. Underneath the location, you see a location ID, it is important that you choose the location with the right location ID from MCS.

 

 

 

 

Motion sensor – PIR

Set the Channel to "pir" and Type to "Presence".

Image Added

Healthy home – Comfort

Create 2 lines for every sensor, since we want to track data from both humidity and temperature sensor within the Comfort sensor:

  • Set the Channel to "humidity" and Type to "Humidity"
  • Set the Channel to "temperature" and Type to "Temperature"

Image Added

Door & Window switch

Set the Channel to "open" and Type to "Pulse".

Image Added