Sensor methodInstallation methodother hardware neededmax installation heightFunctioning methodmax Detection areaIcon decayConfiginfo availableadvised for utilization?
PIR (Tabs)*wireless (tape)hub+sensors per chair2.15m (7ft) to 4m (13.12ft)https://confluence.mcs.be/display/SUM/Tabs+%28Tracknet%29+PIR+Sensor+way+of+measuring4m x 10m (13,12 x 32,81 ft)15minStudioLive Floorplan+Dashboards- possible for utilization in open spaces
- not advised for utilization in meeting rooms (difficult/technical set-up; not possible to detect over-utilisation + risk of false positive/negatives is bigger, eg people standing up in the room or people walking around the chairs while on the phone)
Footfall (Pointgrab)wirednone2.15m (7ft) to 4.5m (14.8ft)in/out-traffic8m x 1m (26 x 3 ft)2minCPMS + StudioLive Floorplanother options are more reliable (footfall method very sensitive)
Actuator LOGIClink (LOGICdata)wireddrive/motorNA

https://confluence.mcs.be/display/SUM/LOGIClink+%28LOGICDATA%29+installation+guide

 

NA15minconfig toolLive Floorplan+Dashboards- possible for utilization in open spaces
- not advised for utilization in meeting rooms (difficult/technical set-up; not possible to detect over-utilisation + risk of false positive/negatives is bigger, eg people standing up in the room or people walking around the chairs while on the phone)
AirthingswirelesshubNAestimate based on size of the room + CO2 => combination of parameters50m2 (538,2 sq ft)15minAirthings + Studionot yet integratedother options are more reliable

 

Setting up Indirect utilization (with PIR): Each SEAT needs to be a real WORKPLACE

  • Make sure each conference room seat corresponds to a workplace
  • Workplaces to be created in/under the correct ROOM object, which in turn should be in the correct room category -> make sure room categories are correctly mapped in Studio
  • Make sure the capacity for meeting rooms is set correctly in Studio (ref Room Capacity)
  • Reminder: Workplaces can only be linked to SVG floorplans in Studio


Ui expand
titleHow to update older MCS config?
Which steps do you need to take if the old config has been set up for your customer?
  • Conference room seats should not exist anymore as rooms -> should be workplaces
  • Workplaces to be created in/under the correct ROOM object, which in turn should be in the correct room category -> make sure MCS room category are correctly mapped in Studio
  • Old zone config should be removed (if wanted to set up “zones”: work with Location Grouping Zones)
  • Make sure the capacity for meeting rooms is set correctly in Studio (ref Room Capacity)
  • Workplaces can only be linked to SVG floorplans in Studio; make sure these are available for the floors that are impacted by this update

 

 

*How is utilization calculated in case both a room and workplaces are linked to a PIR sensor?

  • Occupancy
    • Presence on room level is true in case presence is true for 1 or more workplaces OR if presence is true for the sensor linked to the room itself
      • So if someone walks around in the room, where workplace PIRs are not triggered, but room PIR is triggered -> presence = true
  • Utilization
    • If presence detected on workplaces level AND room level, headcount will only be calculated based upon sum of triggered workplaces. It ignores the room PIR.
      • So if 2 people sit on a chair triggered by workplace PIR, headcount will be 2
    • If presence detected ONLY on room level and not on workplaces, headcount is set to minimum 1
      • So if someone walks around in the room, but workplace PIRs not triggered, headcount is 1

...