Sensor method | Installation method | other hardware needed | max installation height | Functioning method | max Detection area | Icon decay | Config | info available | advised for utilization? |
---|---|---|---|---|---|---|---|---|---|
PIR (Tabs)* | wireless (tape) | hub+sensors per chair | 2.15m (7ft) to 4m (13.12ft) | https://confluence.mcs.be/display/SUM/Tabs+%28Tracknet%29+PIR+Sensor+way+of+measuring | 4m x 10m (13,12 x 32,81 ft) | 15min | Studio | Live Floorplan+Dashboards | - possible for utilization in open spaces - not advised for utilization in meeting rooms (difficult/technical set-up; not possible to detect over-utilisation + risk of false positive/negatives is bigger, eg people standing up in the room or people walking around the chairs while on the phone) |
Footfall (Pointgrab) | wired | none | 2.15m (7ft) to 4.5m (14.8ft) | in/out-traffic | 8m x 1m (26 x 3 ft) | 2min | CPMS + Studio | Live Floorplan | other options are more reliable (footfall method very sensitive) |
Actuator LOGIClink (LOGICdata) | wired | drive/motor | NA | https://confluence.mcs.be/display/SUM/LOGIClink+%28LOGICDATA%29+installation+guide
| NA | 15min | config tool | Live Floorplan+Dashboards | - possible for utilization in open spaces - not advised for utilization in meeting rooms (difficult/technical set-up; not possible to detect over-utilisation + risk of false positive/negatives is bigger, eg people standing up in the room or people walking around the chairs while on the phone) |
Airthings | wireless | hub | NA | estimate based on size of the room + CO2 => combination of parameters | 50m2 (538,2 sq ft) | 15min | Airthings + Studio | not yet integrated | other options are more reliable |
Setting up Indirect utilization (with PIR): Each SEAT needs to be a real WORKPLACE
- Make sure each conference room seat corresponds to a workplace
- Workplaces to be created in/under the correct ROOM object, which in turn should be in the correct room category -> make sure room categories are correctly mapped in Studio
- Make sure the capacity for meeting rooms is set correctly in Studio (ref Room Capacity)
- Reminder: Workplaces can only be linked to SVG floorplans in Studio
Ui expand | ||
---|---|---|
| ||
Which steps do you need to take if the old config has been set up for your customer?
|
*How is utilization calculated in case both a room and workplaces are linked to a PIR sensor?
- Occupancy
- Presence on room level is true in case presence is true for 1 or more workplaces OR if presence is true for the sensor linked to the room itself
- So if someone walks around in the room, where workplace PIRs are not triggered, but room PIR is triggered -> presence = true
- Utilization
- If presence detected on workplaces level AND room level, headcount will only be calculated based upon sum of triggered workplaces. It ignores the room PIR.
- So if 2 people sit on a chair triggered by workplace PIR, headcount will be 2
- If presence detected ONLY on room level and not on workplaces, headcount is set to minimum 1
- So if someone walks around in the room, but workplace PIRs not triggered, headcount is 1
...