On this page you'll find some steps and best practices from the installation highlighted; but please refer to this manual for complete installation instructions.
Questions to ask the customer
Make sure you know exactly what the parking lot looks like / where the sensors will be installed:
- Is it an outdoor or indoor
...
- parking lot? (influences which kind of hub needs to be installed: Indoor hub or outdoor hub (PoE, weather sealed))
- In case of outdoor:
- Is parking lot far away from building or not? (influences where hubs need to be installed)
...
- At which places can power be provided?
- Can PoE be provided?
- Location of poles were hubs can be mounted to
- What does the underground look like? Gravel, stones with holes/grass in between, closed floor? (the surface intended for the installation of the sensor base should be free of any gaps or misalignment)
- In case of indoor:
- Ceiling height
- Construction materials: brick/(reinforced) concrete/other (specify)
- At which places can PoE (or power and ethernet) be provided?
Prerequisites
Before installing the sensors, make sure that
- the necessary infrastructure is working properly: make sure the gateways are switched on, that a stable Internet connection has been established, and that there is a backend connection. The backend, as well as the associated management software, must be functional.
- create Sensor PlanSensor plan (floorplan with dimensions and markings of where the sensors need to come)
- Make sure that all of the required components, as well as the tools, are ready. The sensor base will need to be attached to the substrate (e.g., concrete, asphalt). To do this, Bosch recommends a two component adhesive, eg DELO® PUR 9692 (universal 2 component polyurethane adhesive available in 50 ml and 200 ml cartridges).
...