Table of content
Table of Contents |
---|
Configuration ON Tabs hardware
Hub – Gateway
Configuring the Hub will let you set up the Hub as a router, WIFI client, WIFI extender, or WIFI off. It will also let you choose between DHCP and Static IP for ethernet based connections.
Step 1. Check the firmware version
Step 1.1 Go to the trackio grafana platform
Step 1.2 Open router mamagement
Step 1.3 Locate the hub
Step 1.4 Check if the current firmware version is 1.25.02 or later
Step 2. Factory reset the hub with internet unplugged.
Caution! If the hub is connected to the internet it will reconfigure to the standard MCS configuration
Step 3. Join the hubs initial open Wi-Fi network (Tabs-xxxxxxx)
Step 4. Open the configuration html
Step 5. Follow the configuration steps of the configuration tool.
View file | ||||
---|---|---|---|---|
|
Motion sensor – PIR
This sensor can not be configured.
Legacy (from before 2020 // for use without caps):
There are 5 different parameters that effect the behaviour of a TrackNet motion sensor. Sensitivity, Blind time, pulse counter, window time, and filter type.
Each of these parameters can be altered by sending a downlink to the sensor from the trackio platform.
For calculating the downlink code use the latest version of the downlink encryption sheet.
For configuring multiple sensors at once use the latest version of the downlink configuration program.
Healthy home – Comfort
This sensor can not be configured.
...
Device | Device Type |
Tabs Motion | TrackNet-Motion-v1.3 |
Tabs Comfort | TrackNet-Humidity-v1.3 |
Tabs Door/Window counter | TrackNet-DoorWindow-v1.3 |
...
You can manually add a record via "Add New Device"
Manually add device through location > devices > new: location is filled in. Select Device Type. This will automatically link the device channel (eg PIR for motion sensors). In case of generic sensors, use Advanced to select relevant channels. Advanced is still under construction.
Enter Device ID as mentioned on the sensor. Enter a meaningful Device Name (eg customer_floor number_area). Select a Location from the location tree if this is already known. Next to the already selected (main) Room, you can visualize the incoming data on other, Linked Locations. Imagine having 1 comfort sensor in an open office space and you want to visualize this data on all 8 workplaces in that space: Linked Location needs to contain all 8 workplaces. |
Motion sensor – PIR
Selecting the correct Device Type "TrackNet-Motion-v1.3" should automatically set the Channel to "pir" and Type to "Presence".
...