Difficulty: expert

Content

Table of Contents

...

minLevel1
maxLevel1

Learning Objectives

After reading this article, you’ll be able to:

  • Understand the difference between Occupancy and Utilization concepts used in Workplace

  • Select which sensor solution is most adapted to your use case


What is the difference between the concepts Occupancy and Utilization?

Both concepts are based on occupancy sensor data.

occupancy (eg 50% occupied in 8h time) vs utilization (2 out of 4 chairs)

...

For example a room can be occupied 50% of a day (4 out of 8h) but when only 2 chairs are used out of 4,

 it is utilized 50% against 50% occupation.

...

The real performance is then only 25% (half a day used for half the capacity).

...


As another example, we can take a meeting that went on for 8 hours, where 2 people were in a meeting room with capacity

...

10:

  • Occupancy = 100%

...

  • Utilization = 20%

How to interpret room occupancy in Cobundu : Utilization & Occupancy Matrix

...

for more information on how to configure Room Capacity.

Direct Utilization & Occupancy

“Direct utilization” because the sensor will send information on “the number of people counted in a certain area” to the Workplace platform.

Sensor method

Installation method

other hardware needed

max installation height

Functioning method

max Detection area

Icon decay

Config

info available

advised for utilization?

Pointgrab

wired

none

2.15m (7ft) to 4.5m (14.8ft)

https://confluence.mcs.be/display/SUM/Headcount+%28Pointgrab%29+Sensor+way+of+measuring
The sensor will check every 15 sec – 1 minute for coordinates, the data is uploaded into Cobundu Cloud every 1min: this interval is so low that a person in the room will be captured.

8m x 6m (26 x 20 ft)

2min

CPMS + Studio

Live Floorplan+Dashboards

yes for utilization in meeting rooms or in open spaces

Vergesense wired

wired

device manager

3,66m (12 ft)

Every 1min, a snapshot is taken + data is updated every 1 min; intervall is so low that person in the room will be captured

1 per room or ~ 6 desks (smaller detection area than Pointgrab)

2min

Vergesense + Studio

Live Floorplan+Dashboards

yes for utilization in meeting rooms or in open spaces

Vergesense wireless

wireless

gateway+wireless repeater

3,66m (12 ft)

Every 15min, a snapshot is taken (no average of 15min!) and data is send to Cobundu Cloud every 15min.

1 per room or ~ 6 desks (smaller detection area than Pointgrab)

15min

Vergesense + Studio

Live Floorplan+Dashboards

yes for utilization in meeting rooms or in open spaces

Indirect Utilization & Occupancy

“Indirect utilization” because the sensor will send information on occupancy to the Workplace platform, who will then calculate “the number of people counted in a certain area”.

Sensor method

Installation method

other hardware needed

max installation height

Functioning method

max Detection area

Icon decay

Config

info available

advised for utilization?

PIR (Tabs)*

wireless (tape)

hub+sensors per seat/chair

2.15m (7ft) to 4m (13.12ft)

https://confluence.mcs.be/display/SUM/Tabs+%28Tracknet%29+PIR+Sensor+way+of+measuring

4m x 10m (13,12 x 32,81 ft)

15min

Studio

Live Floorplan+Dashboards

- possible for utilization in open spaces
- not advised for utilization in meeting rooms (difficult/technical set-up; not possible to detect over-utilisation + risk of false positive/negatives is bigger, eg people standing up in the room or people walking around the chairs while on the phone)

Footfall (Pointgrab)

wired

none

2.15m (7ft) to 4.5m (14.8ft)

in/out-traffic

8m x 1m (26 x 3 ft)

2min

CPMS + Studio

Live Floorplan

other options are more reliable (footfall method very sensitive)

Actuator LOGIClink (LOGICdata)

wired

drive/motor

NA

https://confluence.mcs.be/display/SUM/LOGIClink+%28LOGICDATA%29+installation+guide


NA

15min

config tool

Live Floorplan+Dashboards

- possible for utilization in open spaces
- not advised for utilization in meeting rooms (difficult/technical set-up; not possible to detect over-utilisation + risk of false positive/negatives is bigger, eg people standing up in the room or people walking around the chairs while on the phone)

Airthings

wireless

hub

NA

estimate based on size of the room + CO2 => combination of parameters

50m2 (538,2 sq ft)

15min

Airthings + Studio

not yet integrated

other options are more reliable

...

Setting up Indirect utilization (with PIR): Each SEAT needs to be a real WORKPLACE

...

Ui expand
titleHow to update older MCS config?
Which steps do you need to take if the old config has been set up for your customer?
  • Conference room seats should not exist anymore as rooms -> should be workplaces
  • Workplaces to be created in/under the correct ROOM object, which in turn should be in the correct room category -> make sure MCS room category are correctly mapped in Studio
  • Old zone config should be removed (if wanted to set up “zones”: work with Location Grouping Zones)
  • Make sure the capacity for meeting rooms is set correctly in Studio (ref Room Capacity)
  • Workplaces can only be linked to SVG floorplans in Studio; make sure these are available for the floors that are impacted by this update

*How is utilization calculated in case both a room and workplaces are linked to a PIR sensor?

...

  • Presence on room level is true in case presence is true for 1 or more seats OR if presence is true for the sensor linked to the room itself
    • So if someone walks around in the room, where seat PIRs are not triggered, but room PIR is triggered -> presence = true


Utilization

...

  • If presence detected on seat level AND room level, headcount will only be calculated based upon sum of triggered seats. It ignores the room PIR.
    • So if 2 people sit on a chair/seat triggered by workplace PIR, headcount will be 2
  • If presence detected ONLY on room level and not on seats, headcount is set to minimum 1
    • So if someone walks around in the room, but seats PIRs not triggered, headcount is 1

Example

...

Quarter 1

...

Quarter 2

...

Quarter 3

...

Occupancy

...

Room PIR

...

0

...

1

...

1

...

Seat 1 PIR

...

1

...

1

...

0

...

Seat 2 PIR

...

1

...

1

...

0

...

Seat 3 PIR

...

0

...

0

...

0

...

Room occupancy live floorplan

...

TRUE

...

TRUE

...

TRUE

...

Room utilization live floorplan

...

2

...

2

...

1

...

Room utilization count timeslots

...

2

...

2

...

1

...

& Occupancy on Live Floorplan

Occupancy on live floorplan shows: location occupied or not (independent of how many people are in that location)

...

Image Added

Utilization on live floorplan shows: how many people are detected in that location

Image Added

...