Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...


-> The real performance is then only 25% (half a day used for half the capacity).

 


Other example: An 8h meeting for 2 people in a meeting room with capacity=10

  • Occupancy = 100%

  • Utilisation = 20%

 

 



How to interpret room occupancy in Cobundu : Utilization & Occupancy parameters.pptxMatrix

Check Room capacity page for more information on how to configure Room Capacity.

...

Sensor methodInstallation methodother hardware neededmax installation heightFunctioning methodmax Detection areaIcon decayConfiginfo availableadvised for utilization?
PIR (Tabs)*wireless (tape)hub+sensors per seat/chair2.15m (7ft) to 4m (13.12ft)https://confluence.mcs.be/display/SUM/Tabs+%28Tracknet%29+PIR+Sensor+way+of+measuring4m x 10m (13,12 x 32,81 ft)15minStudioLive Floorplan+Dashboards- possible for utilization in open spaces
- not advised for utilization in meeting rooms (difficult/technical set-up; not possible to detect over-utilisation + risk of false positive/negatives is bigger, eg people standing up in the room or people walking around the chairs while on the phone)
Footfall (Pointgrab)wirednone2.15m (7ft) to 4.5m (14.8ft)in/out-traffic8m x 1m (26 x 3 ft)2minCPMS + StudioLive Floorplanother options are more reliable (footfall method very sensitive)
Actuator LOGIClink (LOGICdata)wireddrive/motorNA

https://confluence.mcs.be/display/SUM/LOGIClink+%28LOGICDATA%29+installation+guide

 


NA15minconfig toolLive Floorplan+Dashboards- possible for utilization in open spaces
- not advised for utilization in meeting rooms (difficult/technical set-up; not possible to detect over-utilisation + risk of false positive/negatives is bigger, eg people standing up in the room or people walking around the chairs while on the phone)
AirthingswirelesshubNAestimate based on size of the room + CO2 => combination of parameters50m2 (538,2 sq ft)15minAirthings + Studionot yet integratedother options are more reliable

 


Setting up Indirect utilization (with PIR): Each SEAT needs to be a real WORKPLACE

...

Ui expand
titleHow to update older MCS config?
Which steps do you need to take if the old config has been set up for your customer?
  • Conference room seats should not exist anymore as rooms -> should be workplaces
  • Workplaces to be created in/under the correct ROOM object, which in turn should be in the correct room category -> make sure MCS room category are correctly mapped in Studio
  • Old zone config should be removed (if wanted to set up “zones”: work with Location Grouping Zones)
  • Make sure the capacity for meeting rooms is set correctly in Studio (ref Room Capacity)
  • Workplaces can only be linked to SVG floorplans in Studio; make sure these are available for the floors that are impacted by this update

 

...



*How is utilization calculated in case both a room and workplaces are linked to a PIR sensor?

  • Occupancy
    • Presence on room level is true in case presence is true for 1 or more seats OR if presence is true for the sensor linked to the room itself
      • So if someone walks around in the room, where seat PIRs are not triggered, but room PIR is triggered -> presence = true
  • Utilization
    • If presence detected on seat level AND room level, headcount will only be calculated based upon sum of triggered seats. It ignores the room PIR.
      • So if 2 people sit on a chair/seat triggered by workplace PIR, headcount will be 2
    • If presence detected ONLY on room level and not on seats, headcount is set to minimum 1
      • So if someone walks around in the room, but seats PIRs not triggered, headcount is 1

Example



  

Quarter 1

Quarter 2

Quarter 3

Occupancy

Room PIR

0

1

1

Seat 1 PIR

1

1

0

Seat 2 PIR

1

1

0

Seat 3 PIR

0

0

0

 


Room occupancy live floorplan

TRUE

TRUE

TRUE

 


Room utilization live floorplan

2

2

1


 

Room utilization count timeslots

2

2

1

 


Utilization & Occupancy on Live Floorplan

 


Occupancy on live floorplan shows: location occupied or not (independent of how many people are in that location)

Image Modified 


Utilization on live floorplan shows: how many people are detected in that location

Image Modified