Difficulty: expert
Content
Table of Contents |
---|
Configuration ON Tabs hardware
Hub – Gateway
Configuring the Hub will let you set up the Hub as a router, WIFI client, WIFI extender, or WIFI off. It will also let you choose between DHCP and Static IP for ethernet based connections.
Step 1. Check the firmware version
Step 1.1 Go to the trackio grafana platform
Step 1.2 Open router mamagement
Step 1.3 Locate the hub
Step 1.4 Check if the current firmware version is 1.25.02 or later
Step 2. Factory reset the hub with internet unplugged.
Caution! If the hub is connected to the internet it will reconfigure to the standard MCS configuration
Step 3. Join the hubs initial open Wi-Fi network (Tabs-xxxxxxx)
Step 4. Open the configuration html
Step 5. Follow the configuration steps of the configuration tool.
View file | ||||
---|---|---|---|---|
|
Motion sensor – PIR
There are 5 different parameters that effect the behaviour of a TrackNet motion sensor. Sensitivity, Blind time, pulse counter, window time, and filter type.
Each of these parameters can be altered by sending a downlink to the sensor from the trackio platform.
For calculating the downlink code use the latest version of the downlink encryption sheet.
For configuring multiple sensors at once use the latest version of the downlink configuration program.
Healthy home – Comfort
This sensor can not be configured.
Door & Window switch
This sensor can not be configured.
Deploying sensors in Bohemian
Inquire the list of the sensors (Sensors ID) and import those into Bohemian https://studio.cobundu.com/app/bohemian.
...
If you just filter on the box numbers you’ll see all the sensors in that box.
...
|
Learning Objectives
After reading this article, you’ll be able to:
Set up an excel that makes it’s really easy for the installer to provide location installation information
Use an excel sheet for batch upload of many sensors
Some projects include HUGE amounts of sensors - having the installer paste the stickers-with-sensor-ID on the sensor plan and manually taking it from there might be very time consuming.
If your project has more than (tabs) 50 or 100 sensors, you might consider using excel.
This page describes how to set up an excel that installers can use to quickly enter the (correct) device ID. At the end of an installation day, you will have an excel sheet that contains device ID and location information, allowing you to easily map multiple new devices to Studio.
Tip |
---|
Best practice is to already upload these devices in Studio, as soon as you have the file (so prior to installation), so that anyone accessing Studio:
|
Prerequisites
Set up location master data in IWMS. We’ll need the location unique ID for upload in Studio, but probably the location is known to the customer with “nicer” reference. For example, a meeting room might be called “Louvre”, but unique ID in this case is 910000000007087.
Inquire the list of possible sensors
Most sensors are shipped directly from the manufacturer.
Only for Tabs sensors, your Spacewell Implementation Consultant will be able to indicate which device IDs were shipped (see /wiki/spaces/WM/pages/212828314 ). For them to check this, please communicate box number / cartonID. This is a unique identification number per cardboard box.
Note |
---|
There are tabs 100 sensors in 1 box, so in case your |
...
shipment does not |
...
include a multiple of 100, some IDs mentioned in |
...
the provided list |
...
might not belong to |
...
you. |
...
...
1/2021
...
...
You should use download/upload excel function of the bohemian with correct sensor ID, Sensor Model and organization/tenant.
Even if the Sensor ID on the TAB might have a different format (58A0-CB00-...or E8E1-E100-...), the upload in Studio tenant needs to happen with a dash separating every 2 characters (58-A0-CB-00-... or E8-E1-E1-00-...)
The Sensor ID is in HEX, so only 0-9; A-F characters are used. All letters are in CAPS.
Make sure all your sensors are deployed in Bohemian before you use them in your tenant.
Please be aware that only after the next data package is send, data for this sensor will be visible in your tenant. (This means that depending on time of upload to Bohemian and activity at the customer site, this can take a while.)
Deploying sensors in Studio
Provide the rooms template and floor plans to the customer.
A clear indication of the area where the sensors must/will be installed and additional column for the sensors IDs should be available on the sheet.
As described in the installation guide, note 8 last digits of the sensor number in “Sensor ID #” column.
Concerning the TAB sensor, be aware that there are 2 numbers on a sensor, the ID that starts with 58-A0-CB-00 is the one that we need during the configuration.
...
Warning |
---|
There are no cartonIDs available for the US. |
Prepare Excel
Start by downloading following template:
View file | ||
---|---|---|
|
Expand | ||
---|---|---|
| ||
|
Expand | ||
---|---|---|
| ||
Provided with the CartonID, the Spacewell Implementation Consultant can check /wiki/spaces/WM/pages/212828314 and export the valid sensor IDs.
|
Expand | ||
---|---|---|
| ||
Next to everything described in the sensors specific installation guides and Checklist hardware on-site visit/installation , provide the installer with
|
After completing and receiving the template back it is advised to perform the quality assurance on the sensor IDs to localize the errors.
If all errors are removed, apply the sensor mapping in Studio > Sensor Devices.
You can manually add a record via
Or you can also download the Studio template for quick import.
Caution: When you choose your location, you will see that there are 2 options for the same location. Underneath the location, you see a location ID, it is important that you choose the location with the right location ID from MCS.
Motion sensor – PIR
Set the Channel to "pir" and Type to "Presence".
Healthy home – Comfort
Create 2 lines for every sensor, since we want to track data from both humidity and temperature sensor within the Comfort sensor:
- Set the Channel to "humidity" and Type to "Humidity"
- Set the Channel to "temperature" and Type to "Temperature"
Door & Window switch
Set the Channel to "open" and Type to "Pulse".
Upon installation, fill in the last 6 digits of the sensor ID into column "Sensor ID" in the ROOMS tab.
|
Expand | ||
---|---|---|
| ||
Get the full sensor ID from making a vlookup on the Sensor ID tab |
Expand | ||
---|---|---|
| ||
Copy the Location IDs and the Sensor IDs into the sensor import file. See Configure devices (add, remove, import/export) for more information on batch import. |
Search