Difficulty: expert
Content
Learning Objectives
After reading this article, you’ll be able to:
Set up your IT network as needed for XOVIS installation
Hardware Requirements
XOVIS sensor devices are a wired solution. So make sure that you are allowed/able to foresee cabling and drill holes in the ceiling where needed.
The XOVIS sensor devices need to be powered + connected to the network using Power over Ethernet (RJ 45)
The plug and the sensor need to be free from any mechanical pressure.
The sensor supports Ethernet 10/100MB Full/Half/Auto negotiation based on the IEEE 802.3 standard.
It is highly recommended to set the switch port to auto negotiation.
The sensor is powered by PoE Class 0 compliant to IEEE 802.3af. As defined by the standard, the network switch port needs to provide 15 Watts at 48 V.
Remember: Connecting XOVIS sensor is not possible using 4G or WiFi
Network Requirements
On the network, the devices must have HTTPS & MQTT/TLS access via different ports. Please find below the current “List of IP addresses for outgoing traffic” to know which ports to open.
A Dynamic IP is required.
Search