After reading this article, you’ll be able to:

  • Set up your IT network as needed for XOVIS installation


Hardware Requirements

XOVIS sensor devices are a wired solution. So make sure that you are allowed/able to foresee cabling and drill holes in the ceiling where needed.

The XOVIS sensor devices need to be powered + connected to the network using Power over Ethernet (RJ 45)

  • The plug and the sensor need to be free from any mechanical pressure.

  • The sensor supports Ethernet 10/100MB Full/Half/Auto negotiation based on the IEEE 802.3 standard.

  • It is highly recommended to set the switch port to auto negotiation.

  • The sensor is powered by PoE Class 0 compliant to IEEE 802.3af. As defined by the standard, the network switch port needs to provide 15 Watts at 48 V.

Remember: Connecting XOVIS sensor is not possible using 4G or WiFi

Network Requirements

On the network, the devices must have HTTPS & MQTT/TLS access via different ports. Please find below the current “List of IP addresses for outgoing traffic” to know which ports to open.

A Dynamic IP is required.

 IP Addresses needed for Outgoing traffic

We sync all our hubs to the same open NTP (network time protocol) servers so we have consistent timings in our data warehouse.

We recommend not to use specific IP addresses or DNS destinations in the firewall as they can and probably will change in the future!

→ The ports will remain the same, so we recommend to communicate / open the ports outbound.

Port

Type

Protocol

From

To

Direction

Endpoint/Description

443

TCP

HTTPS

Sensor

HUB

Outbound

HUB Device Control

Whitelist the following URLs:

·        *.xovis.cloud

·        *.xovis.com

·        *.servicebus.windows.net

·        *.cloudapp.azure.com

Azure Cloud IP’s are dynamic

443

TCP

HTTPS

Sensor

Xovis support

Outbound

remotesupport.xovis.com (185.187.120.162)

443

TCP

HTTPS

Sensor

Xovis IoT

Outbound

iot.xovis.com (185.187.120.166)

Mandatory for Update Service & Licensing

443

TCP

HTTPS

Sensor

PIP server

Outbound

pip.xovis.com (185.187.120.6) Product Improvement Program

123

TCP

NTP

Sensor

Timeserver 2

Outbound

time server sync (sensors can also act as as time server)

optional local connections

443

TCP

HTTPS

Client

Sensor

WebUI, REST API, Sensor Explorer

80

TCP

HTTP

Client

Sensor

WebUI, REST API, Sensor Explorer (not recommended)