Ideally, before this sensor is installed, a hub needs to be installed and confirmed working - otherwise the sensor will deplete itself looking for a hub.

Check here the checklist for installation: Checklist for hardware installation

Check our instructions on tape here: Tabs Sensors installation guides

Datasheets can be found here: /wiki/spaces/SUM/pages/492584

 


After installation:

 


A huge chunk of the general introduction on Sensor Installation that has been presented during the Cobundu Summer 2021 Sessions was about Motion Tabs Installation, this is the recording: Summer 2021 Session: Sensor Installation

...

3. Install sensor
•Check the Sensor Plan and decisions from Step 1
•Indicate Sensor IDs on the floorplan > excel for mapping
•"deviating" sensors should be indicated as such on the Sensor Plan
4. Send Sensor Plan with sensor placement indication to Spacewell (scan, picture) for mapping

(Allow time for upload sensor ID and mapping (Spacewell))


5. Quality assessment in the field
Click here for the instructions on Quality Assurance for installation of motion and headcount sensors: Quality Assurance

 

 



View file
nameMotion Tab Placement Guide.pptx
height250

French version : Motion Tab Guide d Installation.pptx (v2020)

 

 



Workplace

Always check the detailed instruction in the Motion Tab Placement Guide.

If the situation you are facing deviates from these instructions/prerequisites, please contact Spacewell. Pictures / Drawings say more than a 1000 words.

 


1.Go to the workplace

2.Remove chair and check prerequisites

...

1.Go to the room
2.Check the height of the room
  • Ceiling height between 2,15m and 4m
  • Length < 4m AND Width < 4m

3.Check the room against the prerequisites. If the prerequisite “Length < 4m AND Width < 4m” is exceeded, please check installation instructions for Meeting Rooms
4.Check for obstructions → contact Spacewell
5.Placement
  • Sensor unpack & placement indication
  • Take sticker from packaging and stick it to the sensor plan
  • Remove sensor from packaging
  • Tape placement
  • Sensor placement on wall of the door, at the entrance of the room
    • Mind that if the door opens to the inside, there might be a reflection on that door. It might be advisable to then place the sensor behind the door (assuming people close the door to start using this space – and thereby trigger the sensor).

Examples

Tape Placement

 


Cap Placement

Workplace (normal)

Workplace (height adjustable table)

...


Sensor Placement