- Sensor unpack & placement indication
- Take sticker from packaging and stick it to the sensor plan
- Remove sensor from packaging
- Tape placement
- Cap placement (different for "normal" vs "height adjustable" tables!)
When it comes to installing caps on motion sensors, we use Loctite Super Glue -3 (all plastics) OR Pattex Super Glue for all plastics (2 steps). Both come with an applicator + glue.
Roughly 70-80 caps can be installed with 1 glue stick, depending how conservative you apply the glue.
Best practices: - First apply the activator, before applying the glue
- Also apply the activator to the base of the sensor where the glue will be touching!
- The instructions for the glue say to wait one minute after applying the activator, don’t just skip the wait time. Wait. If you were to set up an assembly line with a couple of colleagues to glue the caps, make sure that you keep the bags with the correct sensor (upon installation, you will need to take the sticker (number = sensor identification) from the bag to indicate on the sensor plan which sensor has been placed whereto install the cap on the sensor, just pull the strip, exposing the adhesive.
- Sensor placement
- underneath normal table (between 60-80 cm high (not height adjustable to standing table)): vertical/ downwards + perpendicular to table (short side sensor parallel to long side table)
- underneath height adjustable table: longest face of the sensor is parallel to the front of the desk and the lens facing downwards (long side sensor parallel to long side table)
...