Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Installation Flow

General

1. Decide HOW to install
• Check if locations apply to prerequisites described in this document. If there are any deviations to these prerequisites, please contact your Implementation Consultant at Spacewell with a description and, ideally, pictures of the situation

...

French version : Motion Tab Guide d Installation.pptx

 

Workplace

Always check the detailed instruction in the Motion Tab Placement Guide.

If the situation you are facing deviates from these instructions/prerequisites, please contact Spacewell. Pictures / Drawings say more than a 1000 words.

 

1.Go to the workplace

...

  • Sensor unpack & placement indication
  • Take sticker from packaging and stick it to the sensor plan
  • Remove sensor from packaging
  • Tape placement
  • Cap placement
    • When it comes to installing caps on motion sensors, we use Loctite Super Glue -3 (all plastics) OR Pattex Super Glue for all plastics (2 steps). Both come with an applicator + glue.

    • Roughly 70-80 caps can be installed with 1 glue stick, depending how conservative you apply the glue.

    • Best practices:

      • First apply the activator, before applying the glue
      • Also apply the activator to the base of the sensor where the glue will be touching!
      • The instructions for the glue say to wait one minute after applying the activator, don’t just skip the wait time. Wait.
      • If you were to set up an assembly line with a couple of colleagues to glue the caps, make sure that you keep the bags with the correct sensor (upon installation, you will need to take the sticker (number = sensor identification) from the bag to indicate on the sensor plan which sensor has been placed where.
  • Sensor placement underneath table: vertical/ downwards + perpendicular to table (short side sensor parallel to long side table)

Meeting room

Always check the detailed instruction in the Motion Tab Placement Guide.

If the situation you are facing deviates from these instructions/prerequisites, please contact Spacewell. Pictures / Drawings say more than a 1000 words.


1.Go to the meeting room
2.Check the height of the meeting room
  • Ceiling height between 2,15m and 4m
  • Length > 4m OR Width > 4m

3.Calculate the prerequisites by comparing the height to the table (Multiple sensors needed when coverage of 1 sensor is exceeded)
4.Check the room against the prerequisites. If the prerequisite “coverage of 1 sensor” is exceeded, multiple sensors must be installed: please contact Spacewell
5.Check for obstructions → contact Spacewell
6.Placement
  • Sensor unpack & placement indication
  • Take sticker from packaging and stick it to the sensor plan
  • Remove sensor from packaging
  • Tape placement
  • Sensor placement on ceiling, in the middle of the room: perpendicular to room (long side sensor parallel to short side room)

Rooms under 4x4m (bubbles, phone booths, concentration rooms, ...)

Always check the detailed instruction in the Motion Tab Placement Guide.

If the situation you are facing deviates from these instructions/prerequisites, please contact Spacewell. Pictures / Drawings say more than a 1000 words.


1.Go to the room
2.Check the height of the room
  • Ceiling height between 2,15m and 4m
  • Length < 4m AND Width < 4m

3.Check the room against the prerequisites. If the prerequisite “Length < 4m AND Width < 4m” is exceeded, please check installation instructions for Meeting Rooms
4.Check for obstructions → contact Spacewell
5.Placement
  • Sensor unpack & placement indication
  • Take sticker from packaging and stick it to the sensor plan
  • Remove sensor from packaging
  • Tape placement
  • Sensor placement on wall, at the entrance of the room

Examples

Tape Placement

Horizontal
 
Sides
 
Vertical
 
Bottom

 

Cap Placement

 

Sensor Placement

Workplace placement

Table with bar 2


Table without bar

Meeting room placement

Meeting room 1

Meeting room 2

Meeting room 3