...
3. Install sensor
•Check the Sensor Plan and decisions from Step 1
•Indicate Sensor IDs on the floorplan > excel for mapping
•"deviating" sensors should be indicated as such on the Sensor Plan
4. Send Sensor Plan with sensor placement indication to Spacewell (scan, picture) for mapping
(Allow time for upload sensor ID and mapping (Spacewell))
5. Quality assessment in the field
Click here for the instructions on Quality Assurance for installation of motion and headcount sensors: Quality Assurance
View file | ||||
---|---|---|---|---|
|
...
1.Go to the room
2.Check the height of the room
- Ceiling height between 2,15m and 4m
- Length < 4m AND Width < 4m
3.Check the room against the prerequisites. If the prerequisite “Length < 4m AND Width < 4m” is exceeded, please check installation instructions for Meeting Rooms
4.Check for obstructions → contact Spacewell
5.Placement
- Sensor unpack & placement indication
- Take sticker from packaging and stick it to the sensor plan
- Remove sensor from packaging
- Tape placement
- Sensor placement on wall of the door, at the entrance of the room
- Mind that if the door opens to the inside, there might be a reflection on that door. It might be advisable to then place the sensor behind the door (assuming people close the door to start using this space – and thereby trigger the sensor).
Examples
Tape Placement
Cap Placement
Workplace (normal) | |
Workplace (height adjustable table) |
Sensor Placement
Workplace (normal, not height adj.) placement
...