Table of content
Ideally, before this sensor is installed, a hub needs to be installed and confirmed working - otherwise the sensor will deplete itself looking for a hub.
Check here the checklist for installation: Checklist for hardware installation
Check our instructions on tape here: Tabs Sensors installation guides
Datasheets can be found here: /wiki/spaces/SUM/pages/492584
After installation:
- Instructions on Quality Assurance for installation of motion and headcount sensors: Quality Assurance
- Configuration of Tabs sensors on Studio: Tabs (Tracknet) configuration guide
A huge chunk of the general introduction on Sensor Installation that has been presented during the Cobundu Summer 2021 Sessions was about Motion Tabs Installation, this is the recording: Summer 2021 Session: Sensor Installation
Installation Flow
General
(Allow time for upload sensor ID and mapping (Spacewell))
French version : Motion Tab Guide d Installation.pptx (v2020)
Workplace
Always check the detailed instruction in the Motion Tab Placement Guide.
If the situation you are facing deviates from these instructions/prerequisites, please contact Spacewell. Pictures / Drawings say more than a 1000 words.
1.Go to the workplace
- Width of workplace: between 120-180 cm
- CHECK THE DIFFERENCE between "normal" (between 60-80 cm high) and "height adjustable" table installation instructions
- Depth of the table should be minimum 65 cm
- Measure 63 cm deep from the middle of the table
- Check for a flat surface of 3 x 1 cm2
- Check if the flat surface is level
- Check for any obstructions → contact Spacewell
- Sensor unpack & placement indication
- Take sticker from packaging and stick it to the sensor plan
- Remove sensor from packaging
- Tape placement
- Cap placement (different for "normal" vs "height adjustable" tables!): to install the cap on the sensor, just pull the strip, exposing the adhesive.
- Sensor placement
- underneath normal table (between 60-80 cm high (not height adjustable to standing table)): vertical/ downwards + perpendicular to table (short side sensor parallel to long side table)
- underneath height adjustable table: longest face of the sensor is parallel to the front of the desk and the lens facing downwards (long side sensor parallel to long side table)
Meeting room
Always check the detailed instruction in the Motion Tab Placement Guide.
If the situation you are facing deviates from these instructions/prerequisites, please contact Spacewell. Pictures / Drawings say more than a 1000 words.
- Ceiling height between 2,15m and 4m
- Length > 4m OR Width > 4m
- Sensor unpack & placement indication
- Take sticker from packaging and stick it to the sensor plan
- Remove sensor from packaging
- Tape placement
- Sensor placement on ceiling, in the middle of the room: perpendicular to room (long side sensor parallel to short side room)
Rooms under 4x4m (bubbles, phone booths, concentration rooms, ...)
Always check the detailed instruction in the Motion Tab Placement Guide.
If the situation you are facing deviates from these instructions/prerequisites, please contact Spacewell. Pictures / Drawings say more than a 1000 words.
- Ceiling height between 2,15m and 4m
- Length < 4m AND Width < 4m
- Sensor unpack & placement indication
- Take sticker from packaging and stick it to the sensor plan
- Remove sensor from packaging
- Tape placement
- Sensor placement on wall of the door, at the entrance of the room
- Mind that if the door opens to the inside, there might be a reflection on that door. It might be advisable to then place the sensor behind the door (assuming people close the door to start using this space – and thereby trigger the sensor).
Examples
Tape Placement
Cap Placement
Workplace (normal) | |
Workplace (height adjustable table) |
Sensor Placement
Workplace (normal, not height adj.) placement
Meeting room placement
Rooms under 4x4m placement