Difficulty: expert

Content

Learning Objectives

After reading this article, you’ll be able to:

  • Interpret Footfall data on Space Monitor Dashboard


To obtain footfall data, a sensor like Pointgrab or Xovis needs to be configured in footfall mode.

Configuration

  1. Configuration on sensor platform: according to description

  2. Configuration on Workplace platform:

    1. defined count area needs to be linked to a location for data capture

      1. location needs to be in scope of https://spacewell.atlassian.net/wiki/spaces/KB/pages/276168921/Dashboard+settings#Space-Category-Mapping

      2. location needs to have capacity details configured to see utilization details

    2. location may or may not be visualized on a floorplan

      1. also possible to visualize data in a

    3. location

Visualization

In Live Floorplan view

During the whole time where traffic data IN value is higher than OUT value, not only utilization is calculated (as the difference between the two values), but also the location is tracked as “presence detected” (occupancy: yes). During this time, the location will be visualized as an “occupied” location on the floor plan.

In Space Monitor Dashboard

Because presence is detected for that (virtual) location, the occupancy data will also reflect on the dashboard.

If the traffic sensor is monitoring the entry to a meeting room, cafeteria or another closed location, this can easily be compared to all other locations on the floorplan that are tracked with headcount sensors.

Yet if the traffic sensor is monitoring the entry to a building or floor, keep in mind that the location will probably be visualized as the most “occupied” location on the floor (compared to occupancy measured for other locations on the floor).

Good to know

In an ideal scenario, traffic sensor is monitoring the entry to a meeting room, cafeteria or another closed location.

When the traffic sensor is monitoring the entry to a building or floor, keep in mind:

  • the location will probably be visualized as the most “occupied” location on the floor (if occupancy is also measured for other locations on the floor)

  • capacity of the traffic location will be added to the overall “# Meeting Room Seats” on Space Monitor > Utilization sheet.