Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Difficulty: expert

Content

Table of Contents
minLevel1
maxLevel1

Learning Objectives

After reading this article, you’ll be able to:

  • Configure indirect utilization setup with motion sensors

  • Configure the device to its location in the Workplace Platform


Using Browan Motion sensors can be a interesting, non-intrusive way to track (indirect) utilization.

More information on how that works and what is the difference between occupancy and utilization is available on Utilization & Occupancy Matrix

This page describes

  • how to configure the location(s) for which you want to track indirect utilization and

  • how indirect utilization is calculated

Each SEAT (in the meeting room) needs to be a WORKPLACE

  • Make sure each meeting room seat corresponds to a workplace object

  • IWMS "Workplaces" objects to be created in/under the correct ROOM object, which in turn should be in the correct room category -> make sure room categories are correctly mapped in Studio

  • Make sure the capacity for meeting rooms is set correctly in Studio (ref Room capacity Setting the capacity & thresholds of spaces)

  • Reminder: Workplace objects can only be linked to SVG floorplans in Studio

Expand
titleWhich steps do you need to take if the old config configuration method has been set up for your customer?
  • Conference room seats should not exist anymore as rooms -> should be workplaces

  • Workplaces to be created in/under the correct ROOM object, which in turn should be in the correct room category -> make sure the IWMS room categories are correctly mapped in Studio

  • Old zone config should be removed (if wanted to set up “zones”: work with Location Grouping Zones)

  • Make sure the capacity for meeting rooms is set correctly in Studio (see Room capacity Setting the capacity & thresholds of spaces)

  • Workplaces can only be linked to SVG floorplans in Studio; make sure these are available for the floors that are impacted by this update

How is utilization calculated in case both a room and workplaces are linked to a motion sensor?

Occupancy

  • Presence on room level is true in case presence is true for 1 or more seats OR if presence is true for the sensor linked to the room itself

    • So if someone walks around in the room, and the motion sensors allocated to the seats are not triggered, but the room motion sensor is triggered -> presence = true

Utilization

  • If presence detected on seat level AND room level, utilization/headcount will only be calculated based upon the sum of the triggered seats. It ignores the room motion sensor.

    • So if 2 people sit on a chair/seat and trigger the the motion sensor, headcount will be 2

  • If presence is detected ONLY on room level and not on seats, headcount is set to minimum 1

    • So if someone walks around in the room, but seats motion sensors are not triggered, headcount is 1

Example

Quarter 1

Quarter 2

Quarter 3

Room PIR

0

1

1

Seat 1 PIR

1

1

0

Seat 2 PIR

1

1

0

Seat 3 PIR

0

0

0

Room occupancy live floorplan

TRUE

TRUE

TRUE

Room utilization live floorplan

2

2

1

Room utilization count timeslots

2

2

1


Search