Nature of issues
There are several issues that have risen in previous projects.
Issues have risen of the following natures:
- Hub connectivity
- Sensor connectivity
- Inaccurate data
...
Difficulty: starter
Content
Table of Contents | ||||
---|---|---|---|---|
|
Learning Objectives
After reading this article, you’ll be able to:
Start troubleshooting Browan sensor projects
Always learning from projects, this page addresses the most common issues encountered in Browan sensor projects.
Gateway connectivity
In most cases Hub connectivity issues are due to a wrong firewall configuration of the firewall: make sure to check
...
the List of IP addresses for outgoing traffic that is relevant for your gateway.
Make sure the gateway is configured as per the installation instructions.
See LoRa Gateways / Hubs installation guides
Sensor connectivity
...
In most cases where the sensors
...
don’t connect to
...
All these cases were caused by installing the sensors before the hub.
...
the Workplace Platform, either the gateway is not working or the sensors were installed/activated before the gateway was confirmed working.
In the first case (gateway not working): make sure the gateway is connecting to the platform by following above troubleshooting instructions.
In the last case (sensors not connecting to the gateway): remove the battery, wait for the capacitors to be drained (several hours, preferably over night), and insert a fresh battery.
...
Browan Sensors installation guides describes how to replace/change a battery in a tabs sensor.
This page describes more steps to follow concerning sensor connectivity: Sensor
...
...
Make sure to check:
Do the sensor
...
IDs and location comply with deployment?
Are the sensors linked to the correct floor/building?
Are the sensors places optimally according to the
...
How are the sensors placed?
Pictures help:What does a desk look like?
What is the orientation of the sensor?
Are the desks placed in
...
hallways? If so how wide is a
...
hallway?
What are the dimensions of a desk? Height, width, depth?
Are all sensors placed using the same method?
...
Check if Quality Assurance Occupancy/Utilization Sensor has been performed. In case of doubt: go through the steps again
Does each location have the correct number of sensors linked to it
...
(
...
usually 1 desk = 1 motion sensor)
...