Outdoor Micro Installation

Outdoor Micro Installation

Difficulty: expert

Learning Objectives

After reading this article, you’ll be able to:

  • Install the Outdoor Micro gateway


 

Best Practice: configure the device and check connection to Workplace Platform before installation, see Outdoor Micro Configuration

Subject to different environments, the Gateway should be installed in specialized manners. Installation can be roughly divided into two types: wall-mount installation and base-mount installation.

In general, wall-mount installation is the preferable choice since wall-mount installations are less likely to result in a water leak in the roof (you need to make sure there are no water pipes inside the wall and that there are no water towers above the wall).

However, in order to make the right choice, the physical presence of a construction professional and the owner of the building are required in order to evaluate and draw the final decision.

In addition, please note

1. Network cables should not be longer than 100(m). The location of the Gateway will affect the length of the network cable.

2. The height of the antenna must not exceed the 45 degrees cone of protection from the lightning rod.

3. A certain level of attenuation will exist on the RF Cable

4. Waterproof measures must be applied to the installation site.

5. Please ensure that there are no obstacles blocking the antenna and that the antenna is in a vertical state.

6. The way the gateway is installed should make it easy to maintain

7. The gateway, lightning surge arresters (sold separately), and other relative equipment must be properly grounded

Unboxing - content

Basic Equipment - Gateway Installation Diagram

System Architecture Diagram (antenna’s not part of default /standard product)
Diagram of Standard Product Equipment

Per gateway also a LoRa antenna will be shipped

  • 1 LoRa antenna

  • 2 installation rings

Exterior Appearance of the Gateway Device

Outdoor Micro Gateway (Access Point, AP)

Size: 230*200*68 mm

 

  1. Antenna (N-Type female)

  2. Antenna (N-Type female)

  3. 3G/4G mini SIM card

  4. GPS 1.5 GHz Antenna (N-type female)

  5. Ethernet to PoE (connection to the Gateway installed with waterproof connector)

  6. 3G/4G Antenna (N-Type female)

Installation

Device installation can be physically supported by either post mount or wall mount. Installation instructions are stated in the following sections and diagrams.

Outdoor Micro Gateway needs to be placed in the vicinity of the sensors which data it needs to track:

  • if the parking spaces are on the ground floor in an outside location, ideally the Outdoor Micro Gateway is installed in this outside location;

  • if the parking spaces are underground, ideally the Outdoor Micro Gateway is also installed in the basement/next to the parking spaces.

1st possible installation set-up: Post Mounting

Please make sure that all required tools and components are available prior to installation.

Tools: Allen wrenches (M5 and M8) or an adjustable wrench, Philips screwdriver

CODE

Name of Component

QTY

CODE

Name of Component

QTY

1

Outdoor Gateway

1

2

Mounting Base Frame

1

3

Adjustable Plate

1

4

Fixing Plate

1

5

Pack of Screws (includes the necessary types of screws)

1

 

Outdoor Micro Gateway device: Installation steps

 

Please take note NOT to fasten the locking screws and adjustment screws in a tight manner at this point of installation.

 

Install the base frame of the Gateway device against the pole by tightly fastening the fixing plate to the adjustable plate by using locking screws and adjustable screws. (It is recommended to install the Ethernet portal downwards.)

The ground wire portal is situated at the corner of the Gateway with an icon. When the ground wire resistance is less than 5 ohms, the recommended diameter of the ground wire would be less than 6 mm2 .

 

 

Outdoor Micro LoRa Antenna: Installation steps

 

2nd possible installation set-up: Wall Mounting

Please make sure that all required tools and components are available prior to installation.

Required tools:

  • Allen wrenches (M5 and M8) or an adjustable wrench

  • Philips screw

  • impact drill and drill bits (the diameter of the drill bit has to be Φ12.7mm)

  • measuring tape 120mm or longer

  • iron hammer

 

Power and data cables are not included in this product and must be purchased separately.

 

Outdoor Micro Gateway device: Installation steps

 

Outdoor Micro LoRa Antenna: Installation steps

 

Roof installation

Assembling and Securing the Waterproof Connector

The outdoor gateway device requires specialized waterproof Ethernet connectors. The product device comes with one set of waterproof connector components [Waterproof connector - Included in the waterproof packet].

Before the installation, an RJ-45 Ethernet cable and the waterproof connector must be conjoined. Make sure that the Ethernet cable used should be an FTP (Foiled Twisted Pair) outdoor cable and that the gateway device is properly grounded. Please follow the steps below to assemble the waterproof connector. While installing, please ensure that the nut is securely fastened to prevent water or air from entering the gateway device

 

Process of Assembly

Wall-mount Installation on a roof

Base-mount Installation on a roof

 

Functional device

 

After configuration of Micro Outdoor, make sure to connect to power.

Power is supplied to the gateway device via PoE (Power over Ethernet). You can verify whether the PoE device is working correctly by viewing the indicator light.

Power over Ethernet (PoE):

  • Output: connects to the gateway device

  • Input: connects to WAN

  • Check Input Power Requirements in the Prerequisites

 

When using ethernet connection:

  • either connect PoE cable directly from the gateway to the network

  • or connect PoE cable from the gateway to the adapter (connection “data + power out”). Then plug in the adapter into a power socket and connect another PoE cable from the adapter to the network.

 

When using mobile connection: connect PoE cable from the gateway to the adapter (connection “data + power out”). Then plug in the adapter into a power socket.

 


 